How much do you Know About Wireless Remote Ultrasonic Water Meter LoRa?

Jan 10, 2023

Leave a message

How much do you Know About Wireless Remote Ultrasonic Water Meter LoRa?
1. Product Overview

The wireless remote ultrasonic water meter (LoRa) is an intelligent meter composed of a flow sensor, a calculator, and a wireless LoRa transmission module. By processing the temperature difference collected by the sensor and the time difference of the sound wave passing through the fluid, the calculator can accurately measure the flow and can transmit the data wirelessly through the LoRa module.

1ultrasonic water meter (2)
​Mainly used to measure and monitor the flow of water media, such as domestic water, central air-conditioning system water, equipment pipe network water, etc.

2. Technical Parameters
(1) Water Meter Technical Parameters

Nominal diameter(mm)

15

20

25

32

40

Overload flow Q4(m³/h)

3.125

5

7.87

12.5

20

Permanent flow Q3(m³/h)

2.5

4

6.3

10

16

Transitional flow Q2 (m³/h)

0.02

0.032

0.05

0.08

0.128

Minimum flowQ1(m³/h)

0.0125

0.02

0.032

0.05

0.08

Start-up flow(m³/h)

0.005

0.005

0.008

0.01

0.015

Max flow

999999.99

Measuring range

Q3/Q1, R200 (R250 customizable)

Accuracy class

Class B

Pressure loss class

≤0.04 MPa

Working pressure

1.6 MPa

Temperature class

T50

Temperature range

(5~55)℃

Environment class

Indoor, Class B

Electromagnetic class

E1(Residential, Commercial, Industrial)

Power supply

Built-in lithium battery DC 3.6V

Battery life

8-10 years

IInstallation position

Any angle

Display

LCD, 8 digits + additional characters

Installation pitch

U10/D5

Communication interface

RS485 modbus/ LoRa/NB-lOT/LoRaWAN

Protection class

IP68

(2) Wireless LoRa Technical Parameters:

Parameter

LoRa

Power

(2.1~3.6)V

Working frequency

(488~510/865~868)MHz

Transmit power

50mW

Average current

18uA

Transmission distance

1km

Instructions for use

It uses a free public wireless frequency band, and the lora concentrator is required. (The repeater is optional depending on the on-site environment)

Note:

★The lora frequency can be customized according to actual requirements

★The frequency of uploading data is not more than once a day, otherwise it will affect the service life of the battery;

★If the water meter is immersed in water, it will greatly weaken the ability of wireless transmission;

★The management party needs to regularly record and verify the readings of the body part of the water meter.

3. Dimensions

chaoxiao

Nominal Diameter(mm)

DN15

DN20

DN25

DN32

DN40

Length L(mm)

165

195

225

180

200

Length L1(mm)

260

300

346

305

330

Width B(mm)

95

95

95

95

95

Hight H(mm)

86

86

89

100

120

 

4. Display Content

7ultrasonic water meter display content

5. Installation Diagram

20230110101511b50f15a13b5b4fab86e8f4a3896fa2b3

6. Installation Requirements

All parts of the flowmeter (including flow sensor parts and calculator parts) should be installed to avoid exposure, flooding, freezing, and chemical and electromagnetic pollution, and to facilitate disassembly and meter reading.
(1) The system pipeline should be thoroughly cleaned before installation, and the hemp, sand, and other debris in the branch pipe should be removed to avoid flowmeter failure;
(2) The meter body is installed horizontally or vertically, and the distance between the meter and the ground should be less than 0.8m when installed;
(3) The direction of water flow should be consistent with the direction indicated by the arrow on the meter body;
(4) The diameter of the front and rear pipes should be consistent with the diameter of the surface body;
(5) A straight pipe section of 10 times the DN should be left in front of the meter body and 8 times the DN behind the meter (DN is the nominal diameter of the flowmeter).
7. Routine Maintenance
1. After the ultrasonic water meter is installed and used, it should be inspected on a regular basis to check the operation status of the flow meter and whether the battery voltage is normal;
2. When the ultrasonic water meter has been running for 6 years or less than 6 years but the display shows unclear data or indicates low battery (see display instructions)), the battery should be replaced by a professional technician so as not to affect the normal operation of the water meter.
Note: 1. The battery of the ultrasonic water meter should be replaced by a special person, and the user is not allowed to replace it by himself. In case of undervoltage, please contact the manufacturer directly;
2. The frequency of meter reading should not exceed 1 time per day. Too frequent meter readings will affect the service life of the battery.