Product description
Large-diameter ultrasonic water meters have the following uses
1. Measurement and management of industrial processes;
2. Replace the mechanical flowmeter to increase measurement accuracy;
3. Use various high-performance flowmeters in their place.
Product features
▲High measurement frequency;
▲Flow rate can be as low as 100L/h;
▲Dynamic range (Q3/Q1) up to 250:1;
▲Installed in any installation position;
▲Bidirectional metering;
▲Display of error and alarm codes;
▲Optional battery supply;
▲Material ductile cast iron
Outline dimension drawing
Nominal Diameter (mm) |
Length L |
Width W |
Hight H |
Flange Connection |
|||
Flange Diameter |
Bolt Circle Diameter |
Bolt Size-M |
|||||
DN50 |
2 Inch |
200 |
170 |
215 |
170 |
125 |
4-M16 |
DN65 |
2.5 Inch |
200 |
185 |
220 |
185 |
145 |
4-M16 |
DN80 |
3 Inch |
225 |
200 |
235 |
200 |
160 |
8-M16 |
DN100 |
4 Inch |
250 |
220 |
255 |
220 |
180 |
8-M16 |
DN125 |
5 Inch |
250 |
250 |
285 |
250 |
210 |
8-M16 |
DN150 |
6 Inch |
300 |
285 |
335 |
285 |
240 |
8-M20 |
DN200 |
8 Inch |
350 |
340 |
405 |
340 |
295 |
12-M20 |
DN250 |
10 Inch |
450 |
405 |
470 |
405 |
355 |
12-M24 |
DN300 |
12 Inch |
500 |
460 |
525 |
460 |
410 |
12-M24 |
Working principle
Ultrasonic water meter is a new type of water meter that can detect the time difference caused by the change of speed when the ultrasonic beam propagates in the water upstream and downstream, analyze and deal with the flow rate of water, and then calculate the flow rate of water further.
Technical parameters
Nominal diameter(mm) |
50 |
65 |
80 |
100 |
125 |
150 |
200 |
250 |
300 |
Max flow Q4(m³/h) |
31.25 |
50 |
78.75 |
125 |
200 |
312.5 |
500 |
787.5 |
1250 |
Nominal flow Q3(m³/h) |
25 |
40 |
63 |
100 |
160 |
250 |
400 |
630 |
1000 |
Transitional flow Q2(m³/h) |
0.16 |
0.256 |
0.4 |
0.64 |
1.024 |
1.6 |
2.56 |
4.03 |
6.4 |
Min flowQ1(m³/h) |
0.1 |
0.16 |
0.252 |
0.4 |
0.64 |
1 |
1.6 |
2.52 |
4 |
Start-up flow(m³/h) |
0.033 |
0.06 |
0.09 |
0.14 |
0.21 |
0.31 |
0.56 |
0.88 |
1.2 |
Max flow |
9999999.9 |
||||||||
Reverse flow |
9999999.9 |
||||||||
Measuring range |
Q3/Q1, R250(R400 customizable) |
||||||||
Accuracy class |
Class B |
||||||||
Pressure loss class |
≤0.063 MPa |
||||||||
Working pressure |
1.6 MPa |
||||||||
Temperature class |
T30 |
||||||||
Temperature range |
(5~55)℃ |
||||||||
Environment class |
Indoor,Class B |
||||||||
Electromagnetic class |
E1(Residential, Commercial, Industrial) |
||||||||
Power supply |
Built-in lithium battery DC 3.6V |
||||||||
Battery life |
> 10years |
||||||||
Installation position |
Any angle |
||||||||
Display |
LCD, 8 digits + additional characters |
||||||||
Flow profile sensitivity class |
U10/D5 |
||||||||
Communication interface |
RS485 modbus/ Pulse output/GPRS/NB-IOT/Lorawan |
||||||||
Protection class |
IP68 |
||||||||
Tolerable storage temperature |
-20~60℃ |
||||||||
Static power |
10μA |
||||||||
Operating power consumption |
45μA |
Notices for installation
★ Flush pipes before installation to avoid gravels and other foreign objects;
★ Install a valve and filter before the water meter;
★ Do not touch the electrical part or pull wires to avoid damage during installation;
★ Reserve an adequate space for maintenance during installation;
★ When the water meter is installed in a horizontal or inclined way, the ultrasonic flow probe on pipes shall be placed
horizontally, and when installed in a vertical way, make sure the water flows from down to up.
★ Please note that the arrow direction on the pipe shall be consistent with the water flow direction during installation;
★ The joint washer shall be installed correctly to avoid misaligned washer blocking water and affecting accuracy of the water meter;
★ The water meter shall not be installed at the place that may be affected by strong mechanical vibrations;
Special Notices: 1. Be sure to install an on-off valve and filter before the water meter and another on-off valve is recommended after it for maintenance;
★ If the ultrasonic water meter is installed through flange, make sure the parallelism between water meter flange and pipe flange is not more than 0.5% of flange outer diameter and is less than 2mm, otherwise it may result in damage to the water meter.
Installation Figure:
★ Before using this water meter, the pipe must be filled with water, otherwise it will lead to inaccurate or even non-measurement.
★ When installing the water meter, should be reserved length of DN*10 in front of the water meter. Or should be reserved the length of DN*5 behind the water meter.
★ The water meter shall refresh the display at every 4s, and read the water meter (including the starting value and end
value) 4s at least after the valve is closed when test the water meter, otherwise the testing results may be affected;
★ Please make sure the medium flow is within the flow range of the water meter during test and use, otherwise it may result
in damage to the water meter;
★ In case of any malfunction (e.g. metering failed, etc.) during use, please contact the related management department
immediately and do not repair it by yourself;
★ The product is designed with a disposable anti-disassembly seal which shall be removed only by appointed personnel, or
otherwise it shall be excluded from the free after-sales service.
Composition
Meter display content
P1: In the last interface of P1, keep covering the sensing area for more than 3S to enter P2 and repeat this operation to enter P3 ,P4
P2:Cumulative flow of historical month
P3:For internal debugging and testing, it does not have any meaning
P4: Test status
Mode | No. | Display description |
P1 | 1 | Cumulative flow |
2 | Temperature | |
3 | Size | |
4 | Flow rate | |
5 | Negative cumulative flow | |
6 | Net cumulative flow | |
7 | Working time | |
8 | Sensor status | |
9 | Power voltage | |
P2 | cumulative flow of historical month | |
P3 | For internal debugging and testing,it dose not have any meaning | |
P4 | 1 | Cumulative flow |
2 | Coefficient | |
3 | Flow rate | |
4 | Working time |
Note:The display interface of the meter is subject to change for customization or upgrading.
Interface/Communication
The ultrasonic water meter will have one of the many options output pre-selected when placing the order. This section will describe each output:
• Modbus/RS485 output
• Pulse output
• Wireless output
Modbus/RS485 output
Pulse Output (Battery Powered)
• Pulse output parameters:
• Open-drain output
• Voltage 3V~24V
• Low level single pulse
• Pulse duration: 5ms
GPRS/NB-IOT wireless transmission
Data name |
Parameter |
Static power |
15uA |
Power consumption |
60mA@RX |
Control box |
Plastic |
Online method |
Touch or automatically go online |
Reporting interval |
How often to send data: once every three days or once a day (The higher the sending frequency, the shorter the battery life) |
Sending bit |
0.1m³ |
Power supply |
3.6VDC |
Battery capacity |
8.5Ah |
Uplink interface |
GPRS/NB-IOT |
Downlink interface |
RS485 |
Data name |
Parameter |
Static power |
15uA |
Power consumption |
60mA@RX |
Control box |
Plastic |
Online method |
Touch or automatically go online |
Reporting interval |
How often to send data: 1~144 h can be set(Default once a day) Can be connected to pressure collection device |
Sending bit |
0.1m³ |
Power supply |
3.6VDC |
Battery capacity |
18Ah/36Ah |
Uplink interface |
GPRS/NB-IOT |
Downlink interface |
RS485 |
Factory
Packing and inventory
Our client
Why S.H.Meters
Certification
Hot Tags: Ultrasonic Smart Water Meter Industrial Sewage Water Meter, suppliers, manufacturers, factory, wholesale, buy, price, bulk, for sale, Water Meter Series, Buy Ultrasonic Water Meter R250, Buy Bulk RS485 water meter, ultrasonic water meter dn50 suppliers, Dn100 Rs485 Modbus Water Meter Ultrasonic price, smart bulk water meter manufacturers